Infiniti

Home » Infiniti
  • 2010 Infiniti FX35

    Infiniti FX35
    Mileage
    153,934
    Service Date
    2/13/2026
    Services Performed
    • ` -Vehicle started right up but has a rough / erratic idle with the Engine Light being active. -Exhaust is rattling, sounds like a possible leak as well. -Started to go on a Test Drive and can feel the Vehicle having a pretty bad Misfire. -Misfire at idle but seems to go away / clear up when at park when off idle. -Vehicle does not have any Misfire Data to be seen but all other Data that can be seen seems to be normal. -Verified Oil Level is good, but looks a bit dark already since just recently changed 1,000 Miles ago. -Cleared Fault Codes and then let Vehicle get to Operating Temperature while applying some throttle to achieve about 1,000 RPMs where it seemed to run normal. -Let the Vehicle sit at idle until the Engine light came back active, set a P0301
    • Cylinder 1 Misfire -Located Cylinder 1 (Passenger's Side), removed Ignition Coil and Spark Plug for inspection. -Looks that all 6 Cylinders have new Denso Ignition Coils, which Service History shows 5 Ignition Coils and Spark Plugs were installed on 8/28/2025 at 149,953 Miles. -Swapped Spark Plug and Ignition Coil with Cylinder 2 (Driver's Side), cleared Fault Code and let Vehicle run until a Code was set. -DTC P0302
    • Cylinder 2 Misfire, was set showing the Misfire moved with the Coil and Plug. -Requires Warranty of the Ignition Coil and Spark Plug. -Recommend performing an Induction Service. `
    • SPARK PLUG – Remove & Replace
    • AIR / FUEL INDUCTION SERVICE – Includes Cleaning the Throttle Body of Carbon, Cleaning the Mass Air Flow Sensor, add Fuel Additive in the tank, performing Chemical Cleaning through the Air Induction System to Clean Carbon Buildup in the top of the Engine.
     
    Joseph C. gave our service a 5 star review on 2/13/2026
  • 2020 Infiniti QX60

    Infiniti QX60
    Mileage
    88,247
    Service Date
    12/10/2025
    Services Performed
    • ` Any Warning Indicators / Lights present? – No Is the Vehicle a Hybrid or EV? – No Is the System Currently Cooling upon Arrival? -Yes Are the HVAC Controls Manual or Automatic? – Automatic Does the Vehicle have Dual Climate Control? – Yes Does the Vehicle have Rear A/C? – No Does ALL Blower Speeds work Properly? -Yes Does the Temperature Control work Properly? -Yes Do all Vent Modes work Properly? – Yes Does Re-Circulation work Properly? – Yes Does the Vehicle have a Cabin Air Filter? -Dirty Does the Vehicle have Both Service Valve Caps? -Yes Type of Refrigerant Required – R134a Compressor Currently Running? – Yes System Pressure coming in at idle – 30/80 psi(cool outside) What is the Condition of the Belt? – OEM Evacuated Charge Amount – 0.44lbs Was the System Contaminated? – No Manufactures System Capacity (recharged) -1.38 lbs Running Pressures After Recharge – 30/100 psi(cool outside) Fan Clutch working properly? – na Electric Cooling Fan Working Properly? -Yes System Cooling after Charged? – Yes Stored Diagnostic Trouble Codes Present? -Yes but not for hvac. b2631,b2668 sunload sensor fault Is any Additional Diagnostics Requires? -No Leak Check Found – A/c compressor is leaking from the main body seal. Additional Technician Notes: Recommend replacement of A/c compressor, drier and expansion valve for best cooling capability and warranty purposes. Recommend flushing the system thoroughly and evacuating and recharging the system. Recommend replacement of serpentine belt and cabin air filter also **left front inner fender cover missing on arrival `
    • A/C COMPRESSOR – Remove & Replace – [DOES NOT include Air Conditioning System recover, evacuate and/or recharge.]
    • (Combination) – RECEIVER DRIER – Remove & Replace Condenser Assembly – [Includes: R&I Bumper Cover.]
    • EVAPORATOR EXPANSION VALVE – Remove & Replace – Front – [Includes: R&I Air Conditioning Evaporator Assembly. DOES NOT include Air Conditioning System charge.]
    • AIR CONDITIONING SYSTEM FLUSH – Disconnect necessary Lines & Components to properly Flush Entire System – [Includes Flushing Condenser, Evaporator Core, All Lines & Hoses]
    • A/C SYSTEM EVACUATION & RECHARGE – Complete System Evacuation, Vacuuming System, Refrigerant Re-Charged to Manufacturer's Specifications, and Followed by a Complete System Leak Check.
     
    Brian R. gave our service a 5 star review on 12/10/2025